| ID | bit | Description - when bit is set |
| A flags |
| a | 1 | Date in download is displayed as mm/dd/yy (normally dd/mm/yy) |
| a | 2 | Date in download is displayed as yy/mm/dd (normally dd/mm/yy) |
| a | 3 | Suspend all logging |
| a | 4 | Enable burst mode logging |
| a | 5 | Omit User ID in welcome message |
| a | 6 | Enable all addresses (normally alphanumeric addresses) |
| a | 7 | Burst length logging is for 10 minutes |
| a | 8 | Burst length logging is for 1 minute |
| B flags |
| b | 1 | No flow control (normally Xon/Xoff) |
| b | 2 | Download takes priority of resources (normally logging) |
| b | 3 | Omit first line in download heading (normally send) |
| b | 4 | Omit second line in download heading (normally send) |
| b | 5 | Voice reading resolution is bit 0 (Low = 01, medium = 10, high = 11) |
| b | 6 | Voice reading resolution is bit 1 (Low = 01, medium = 10, high = 11) |
| b | 7 | Delineation character bit 0 (comma = 01, semicolon = 10, tab = 11) |
| b | 8 | Delineation character bit 1 (comma = 01, semicolon = 10, tab = 11) |
| C flags |
| c | 1 | Omit time group in page display (normally send) |
| c | 2 | Omit address in page display (normally send) |
| c | 3 | Omit type in page display (normally send) |
| c | 4 | Omit units in page display (normally send) |
| c | 5 | Send full units (normally send abreviated units) |
| c | 6 | Send address in decimal (normally send address in ASCII) |
| c | 7 | Time display is hh:mm (normally hh:mm:ss |
| c | 8 | Readings are low resolution (normally high resolution) |
| D flags |
| d | 1 | Send only max/min/ave/totals in download (normally send all) |
| d | 2 | Omit max/min/ave/totals in download (normally send all) |
| d | 3 | LCD readings are direct (normally by fast binary conversion) |
| d | 4 | Schedule "i" is 6 minute interval (normally 5 minute) |
| d | 5 | Omit LCD "Log now" acknowledgement |
| d | 6 | Logger waits for sensor replies (radio link in use) |
| d | 7 | 4 readings per LCD screen (normally 2) |
| d | 8 | Disable Monibus collision protection |
| E flags |
| e | 1 | Inhibit sleep mode (normally permit logger to sleep) |
| e | 2 | Enable auto changing of dumb sensors to smart mode |
| e | 3 | Sends "End" after data download has finished |
| e | 4 | Date time format = Julian date, military time |
| e | 5 | Skip logging of 09:00 to 09:00 rainfall totals |
| e | 6 | Log zero readings from event sensors (normally skip) |
| e | 7 | Current readings are direct (normally by fast binary conversion) |
| e | 8 | Auto-search at 23:55 hours |
| F flags |
| f | 1 | Virtual Evapotransporation Sensor ON |
| f | 2 | Priestly-Taylor ET model(normally Penman-Montieth) |
| f | 3 | Albedo coefficient is 0.05 for forests (normally 0.20 for crops) |
| f | 4 | Stress Index MK I (default = latest version) |
| f | 5 | Virtual Animal Comfort/Stress Index Sensor ON |
| f | 6 | Virtual Accumulated Heat Load Index ON (HLI) |
| f | 7 | Virtual Battery Voltage Sensor ON |
| f | 8 | Virtual current sensor ON |
| G flags |
| g | 1 | Virtual Dew Point Sensor ON |
| g | 2 | Virtual Dew Point Sensor reports in deg F (normally deg C) |
| g | 3 | GPS sensor activate |
| g | 4 | GPS UTC time updates logger clock |
| g | 5 | date & time seperated by comma in download |
| g | 6 | download only comments |
| g | 7 | download excludes comments |
| g | 8 | Schedule k = 20 minute interval (default = 15) |
|
H flags - password is required |
| h | 1 | Password Access to logger settings menu is ON |
| h | 2 | Invisible Menus ON |
| h | 3 | Send modem initialisation string on RS232 |
| h | 4 | |
| h | 5 | |
| h | 6 | |
| h | 7 | |
| h | 8 | |