µSmart Logger option flags

These options can be changed by using the logger menu 4,6  A B C D E F G H I
 
Location Set = 1 Set = 0
Register A
1 mm/dd/yy dd/mm/yy
2 yy/mm/dd dd/mm/yy
4 yy/mm/dd dd/mm/yy
3 inhibit all logging enable logging
4 burst mode logging enabled burst mode logging inhibited
5 spare spare
6 all addresses alpha-numeric addresses only
7 10 minute burst hour burst
8 1 minute burst hour burst
Register B
1 Xon/Xoff disabled Xon/Xoff enabled
2 priority logging download priority
3 Omit download header 1 Include download header 1
4 Omit download header 2 Include download header 2
5 voice reading resolution bit 0 (Low = 01, medium = 10, high = 11)
6 voice reading resolution bit 1  
7 column delineator bit 0 (comma = 01, semicolon = 10, tab = 11)
8 column delineator bit 1  
Register C top
1 Omit page display time Include page display time
2 Omit page display address Include page display address
3 Omit page display sensor type Include page display sensor type
4 Omit page display units Include page display units
5 Show full units Show abbreviated units
6 Show decimal address Show ASCII address
7 hh:mm time display hh:mm:ss time display
8 low resolution readings high resolution readings
Register D top
1 Download comments Download all line types
2 Download without min, max, averages Download with min, max, averages
3 LCD readings are ASCII LCD readings are binary
4 Schedule i is 6 minutes Schedule i is 5 minutes
5 Hide LCD Log response Show LCD Log response
6 spare spare
7 LCD shows 4 x readings LCD shows 2 x readings
8 Disable Monibus collsion detection Enable Monibus collsion detection
Register E top
1 Disable logger sleep mode Enable logger sleep mode
2 Enable sensor new command Disable sensor new command
3 Download end flagged Download end not flagged
4 Julian day, military time Standard date and time
5 Hide 9AM rain totals Show 9AM rain totals
6 Log zero event readings Don't log zero event readings
7 Current readings are ASCII Current readings are binary
8 Automatic sensor search at 23:55 No automatic sensor search
Register F top
1 Enable evapotranspiration sensor Disable evapotranspiration sensor
2 Priestly-Taylor ET calculation Penman-Montieth ET calculation
3 Albedo coefficient 0.05 ( forest ) Albedo coefficient 0.20 ( crops )
4 HLI calculation 1 HLI calculation 2
5 Enable HLI sensor Disable HLI sensor
6 Enable AHLU sensor Disable AHLU sensor
7 Enable logger battery sensor Disable logger battery sensor
8 Enable logger current sensor Disable logger current sensor
Register G top
1 Enable dew point sensor Disable dew point sensor
2 Fahrenheit dew point Celcius dew point
3 Enable GPS sensor Disable GPS sensor
4 Synch logger clock to GPS UTC Ignore GPS UTC
5 dd-mm-yy, hh:mm:ss dd-mm-yy hh:mm:ss
6 Download comments no data Download with comments
7 Download without comments Download with comments
8 Schedule k is 20 minutes Schedule k is 15 minutes
Register H - PIN required top
1 Lock setup menus with PIN Allow access to setup menus
2 Hide menu text Show menu text
3 Send modem string at xx:x3 Not sent
4 Enable web reporter Disable web reporter
5 Hide menus after web access Show menus
6 Enable Hydrotel reporter Disable Hydrotel reporter
7 spare spare
8 spare spare
Register I top
1 Extend sensor report timeout Default sensor report timeout
2 Extend GPS power until location received Normal GPS power timeout
3 Enable precision event sensor Disable precision event sensor
4 Logger uses UTC time Logger uses standard time
5 Show precision event on LCD Not shown
6 spare spare
7 spare spare
8 spare spare